Protecting Capstone’s Erie Shores Wind Farm from rotor shaft failure

  • Bespoke shaft monitoring a custom variant built to detect rotor flange cracking
  • Full-site protection tailored monitoring deployed across all 65 turbines
  • Automatic shutoff ONYX’s first PLC relay shuts down turbines automatically
Aerial view of a wind farm located in cultivated fields crossed by a road

Capstone Logo

At a glance

  • A failure event that led to a site shutdown
    A rotor liberation caused by a rotor crack took Erie Shores offline for close to a month while all other 65 turbines were individually inspected.
  • ONYX’s first autonomous shutdown capability
    The project led to ONYX’s first PLC shutoff relay, giving turbines the ability to shut down automatically if crack symptoms are detected.
  • An estimated $1.5M direct savings in inspection costs
    Shaft CMS replaces a recurring non-destructive testing (NDT) inspection programme estimated at $200,000–$500,000 per cycle, eliminating the need for scheduled inspection visits entirely.

Products

  • fleetMONITOR  – with custom, configurable alarm thresholds and automated email alerting to operations team
  • Custom Shaft CMS – Automated PLC shutoff relay

Talk to an engineer today

Company

Capstone is generating Canada’s low-carbon future, driving the energy transition forward through creative thinking, strong partnerships, and a commitment to quality and integrity in how they do business. A developer, owner, and operator of clean and renewable energy projects across Canada, Capstone’s portfolio includes approximately 1.1 GW gross installed capacity across 36 facilities, including wind, solar, hydro, biomass, and natural gas power plants from coast-to-coast. 

Erie Shores Wind Farm consists of 65 GE SLE1.5 wind turbines located along the north shore of Lake Erie in Ontario. All electricity generated at the site is sold to the Ontario’s Independent Electricity System Operator (IESO) under a power purchase agreement, making Erie Shores one of the largest wind power facilities in Ontario and representing approximately 4.8% of the province’s installed wind power capacity. 

Challenge

One of Capstone’s turbines at Erie Shores experienced a rotor liberation caused by a crack in the rotor flange, taking the entire site offline for close to a month while each turbine was individually inspected before it could be brought back online. The failure itself occurred after 19 years of operation with no prior indication of a fault, which makes it particularly difficult to identify through conventional inspection schedules. 

One potential option was a recurring non-destructive testing inspection programme to get the site back online. At approximately 300 hours per year and between $200,000 and $500,000 per inspection cycle, that approach would have cost an estimated $1.5M over five years with no guarantee of identifying a developing crack between visits. 

Beyond the financial cost, the safety risk to up-tower and down-tower teams meant that returning to an inspection-only regime was not a sufficient answer.  

Solution

ONYX Insight was selected to develop a variant of its custom instrumentation system for the Main Shaft application, adapted specifically to detect crack symptoms in the rotor flange. The decision came down to several factors: proven experience in main shaft monitoring, an existing body of case studies to support the methodology, and a willingness to develop a solution tailored to Capstone’s specific failure mode and requirements.  

The system delivers multiple real-time measurements between the nacelle to hub via 4G connectivity, with monitoring outputs and email alerts routed directly to Capstone’s engineering and operations teams when thresholds are approached.  

The most significant element of the deployment is ONYX’s newly developed PLC shutoff relay, which integrates with the data acquisition unit to allow individual turbines to shut down autonomously if readings indicate symptoms consistent with crack development. 

Aerial view of a wind farm located in cultivated fields crossed by a road

The detail behind the estimated $1.5m in direct savings

Feature Before - NDT Inspection Programme After - ONYX Custom Shaft CMS
Coverage
Point-in-time snapshots Continuous, real-time based operating conditions
Frequency Required
Annual or bi-annual Always on, inspections reserved to validate known issues
Inspection Hours per year
Approximately 300 hours
Estimated inspection cost per cycle
$200,000-500,000
Crack detection between visits
None Yes, with automatic turbine shutdown
Coverage
Before - NDT Inspection Programme Point-in-time snapshots
After - ONYX Custom Shaft CMS Continuous, real-time based operating conditions
Frequency Required
Before - NDT Inspection Programme Annual or bi-annual
After - ONYX Custom Shaft CMS Always on, inspections reserved to validate known issues
Inspection Hours per year
Before - NDT Inspection Programme Approximately 300 hours
After - ONYX Custom Shaft CMS
Estimated inspection cost per cycle
Before - NDT Inspection Programme $200,000-500,000
After - ONYX Custom Shaft CMS
Crack detection between visits
Before - NDT Inspection Programme None
After - ONYX Custom Shaft CMS Yes, with automatic turbine shutdown

“ONYX played a fundamental role in safely bringing Erie Shores back online following the rotor liberation event. Their ability to develop a tailored monitoring solution quickly, and have it ready for deployment across the site in a timely manner, gave us a confident path forward.

Knowing the system will autonomously shut down a turbine if crack symptoms are detected removes the reliance on manual intervention. Beyond the immediate response, the solution has significantly reduced our O&M costs and ensures we can continue maximising power generation from the site.”

Derek DeLeye
Ontario Regional Manager – Capstone Wind Division,

Capstone Logo

Derek

Benefits

The installation of Shaft CMS across Erie Shores gives Capstone continuous, real-time oversight of a failure mode that previously offered no advanced warning. Key outcomes include: 

  • Inspection costs and hours eliminated.  
    Rather than committing to manual NDT inspections across the site year on year, Shaft CMS handles continuous coverage automatically, saving an estimated 300 hours of inspection time per year and an estimated $1.5M over the five-years. 
  • Turbines that protect themselves  
    The PLC shutoff relay acts on live data, shutting down individual turbines autonomously if readings point to developing damage, without waiting for human sign-off. 
  • More years from an established site.  
    With continuous monitoring underpinning safe operation, Capstone can keep generating from Erie Shores with confidence. 
  • A capability with broader potential.  
    The PLC shutoff relay developed for this project has potential applications across other failure modes and turbine platforms.

“When Capstone came to us, they had an urgent and specific problem.

Working closely with their team to understand the failure mode meant we could move quickly, integrating automated alerting directly into their operations workflows and delivering a solution that enables Capstone to operate confidently, knowing their assets are protected while providing a direct saving an estimated $1.5m in inspection costs over the next five years.”

Colin McNichols
VP Engineering North America

ONYX Logo Black Colour X

Colin

 

Work with ONYX on your specific challenge

Shaft CMS is not a standard off-the-shelf product. It is a custom-engineered solution developed specifically in response to Capstone’s requirements.

If your site is facing a similar shaft monitoring challenge, or if your fleet is experiencing a serial defect that falls outside what traditional condition monitoring system currently covers, ONYX can work with you to develop a solution built around your specific failure mode and operational context.

Talk to an engineer today